Paris Baguette Singapore Pte Ltd.

Angio-Seal™ VIP


Simple.Proven. Fast Sealing1.

Angio-Seal™ VIP is indicated for closing and reducing time to hemostasis at the common femoral arterial puncture site (lumen diameter >4mm) in patients who have undergone diagnostic angiography procedures or interventional procedures using

  • an 8 French or smaller procedural sheath for the 8Fr Angio-Seal device
  • or a 6French or smaller procedural sheath for the 6Fr Angio-Seal device.

Angio-Seal™ VIP is also indicated to allow patients to ambulate safely as soon as possible after sheath removal and device placement, following a diagnostic angiography and/or interventional procedures.

CONTACT A REPRESENTATIVE

Characteristics

Angio-Seal contains 3 bioabsorbable components for active arteriotomy closure:

  • Hemostasis is achieved by sealing the arteriotomy with a bioabsorbable anchor and bioabsorbable collagen plug, held together by a bioabsorbable suture.
  • All implantable components resorb within 90 days.2
  • Arterial flow is not compromised, no evidence of chronic scar tissue or inflammation.

Proven

After more than 20 years on the market and numerous randomized clinical trials, Angio-Seal™ proved:

  • high deployment & hemostasis success rate3
  • to provide safe & effective closure of the femoral access site4
  • to have lower complication rates than manual compression5 & other VCDs6

Fast Sealing

Versus manual compression, Angio-Seal significantly reduces:

  • Time to hemostasis4
  • Time to ambulation1
  • Time to discharge7

Preparation

Video instructions

General specifications

Content Vascular closure device
Insertion sheath
Arteriotomy locator
70 cm guidewire with “J” straightener
Angio-Seal 6 Fr dimension Sheath diameter: 2.0mm (6 Fr)
Guidewire diameter: 0.89mm (0.035 in)
Angio-Seal 8 Fr dimension Sheath diameter: 2.7mm (8 Fr)
Guidewire diameter: 0.96mm (0.038 in)
MRI safe Yes
Storage temperature Between 15°C to 25°C
Shelf life One year after sterilization
Sterilisation process Gamma radiation (Do not re-sterilize)
Units per box 10

Item specifications

Item reference French size Guidewire diameter (in)
610132 6 0.035
610133 8 0.038

References

1Martin J.L. et al. Catheter Cardiovasc Interv. 2008 Jan 1;71(1):1-5

2Tellez A. et al. EuroIntervention. 2010;5(6):731-6.

3Manolis A.S. et al. Indian Heart Journal. 2016; 68:529-538.

4Wong H.F. et al. AJNR Am J Neuroradiol. 2013 Feb;34(2):397-401.

5Tavris D.R. et al. J Invasive Cardiol. 2012 Jul;24(7):328-34

6Jones L.E. et al. Surg Technol Int. 2015 Nov;27:32-44.

7Veasey R.A. et al. International Journal of Clinical Practice, 62(6), 912–918.