Paris Baguette Singapore Pte Ltd.

Glidesheath Slender™


Expanding Transradial Access for more Patients

Glidesheath SlenderTM offers the smallest option for procedures requiring 5, 6 and 7 Fr sheaths.1 The proprietary thin-wall technology reduces the outside diameter of the introducer sheath by 1 Fr while maintaining a larger inner-diameter equivalent. The sheath is designed to maximize procedural outcomes, supporting transradial intervention every day.

CONTACT A REPRESENTATIVE

Characteristics

Increase your radial access options with Glidesheath Slender™

  • Ultra-thin wall leading to a 1 Fr reduction in outer diameter
  • Designed towards minimizing mechanical irritation to the artery
  • Result in less penetration resistance than conventional sheaths1,2

Thin-wall technology expands radial access for more patients

  • Perform diagnostic and interventional procedures without upsizing to a larger sheath
  • Provide easy radial access, especially in women with smaller radial arteries1,3
  • A smaller diameter sheath reduces the arteriotomy size, to enhance post-procedure haemostasis1

Thin-wall technology expands radial access for more complex PCI

  • 5Fr for invasive PCI for patients with small radial artery diameter
  • 6Fr as standard size for daily practice PCI
  • 7Fr for complex PCI & larger devices (rotablation, bifurcation, left main, CTO, etc.)

MCoat™: Terumo’s hydrophilic coating

  • Ease of insertion and removal
  • Reduce penetration resistance compared to conventional sheaths4
  • Reduce friction between the vessel and the introducer2
  • Lower risk of adverse events such as radial artery occlusion1,2
  • Glidesheath Slender™ demonstrates superior and consistent lubricity, and lubricity durability over time5

Clinical evidence

DIStal versus COnventional RADIAL access for coronary angiography and intervention (DISCO RADIAL)

Aminian A. et al. JACC Cardiovasc Interv 2022

Randomized Comparison Between Radial and Femoral Large-Bore Access for Complex Percutaneous Coronary Intervention

Meijers, T.A. et al. J Am Coll Cardiol Intv. 2021;(12):1293-303.

Item specifications

This kit contains sheath, dilator, plastic or spring mini guidewire, plastic IV catheter (entry needle) or a metallic entry needle.

Outer Diameter Sheath Length Entry Needle-Diameter Entry Needle-Length Entry Needle-Type Mini Guidewire-Type Mini Guidewire-Diameter Mini Guidewire-Length Units/Box Code
5 Fr 10 cm 20 G
0.9 mm
35 mm Metallic Entry Needle Spring 0.025 in

0.64 mm
45 cm 5 RM*RS5J10PQ
5 Fr 10 cm 20 G
0.9 mm
51 mm Plastic IV Catheter Plastic 0.025 in

0.64 mm
45 cm 5 RM*ES5J10SQ
5 Fr 10 cm 21 G
0.8 mm
35 mm Metallic Entry Needle Spring 0.021 in

0.53 mm
45 cm 5 RM*RS5F10PQ
5 Fr 10 cm 22 G
0.7 mm
32 mm Plastic IV Catheter Plastic 0.021 in

0.53 mm
45 cm 5 RM*ES5F10SQR
5 Fr 10 cm 22 G
0.7 mm
35 mm Entry Needle Spring 0.018 in

0.46 mm
45 cm 5 RM*RS5C10PQ
5 Fr 16 cm 21 G
0.8 mm
35 mm Metallic Entry Needle Spring 0.021 in

0.53 mm
80 cm 5 RM*RS5F16PQ
6 Fr 10 cm 20 G

0.9 mm
32 mm Plastic IV Catheter Plastic Shortangle 0.025 in 0.64 mm 45 cm 5 RM*ES6J10HQS
6 Fr 10 cm 20 G

0.9 mm
35 mm Metallic Entry Needle Spring 0.025 in 0.64 mm 45 cm 5 RM*RS6J10PQ
6 Fr 10 cm 20 G

0.9 mm
51 mm Plastic IV Catheter Plastic 0.025 in 0.64 mm 45 cm 5 RM*ES6J10SQ
6 Fr 10 cm 20 G

0.9 mm
51 mm Plastic IV Catheter Spring 0.025 in 0.64 mm 45 cm 5 RM*ES6J10PQ
6 Fr 10 cm
21 G
0.8 mm
35 mm Metallic Entry Needle Spring 0.021 in 0.53 mm 45 cm 5 RM*RS6F10PQ
6 Fr 10 cm 22 G

0.7 mm
25 mm Plastic IV Catheter Plastic 0.021 in 0.53 mm 45 cm 5 RM*ES6F10SQ
6 Fr 10 cm 22 G

0.7 mm
32 mm Plastic IV Catheter Plastic 0.021 in 0.53 mm 45 cm 5 RM*ES6F10SQR
6 Fr 10 cm 22 G

0.7 mm
35 mm Metallic Entry Needle Spring 0.018 in 0.46 mm 45 cm 5 RM*RS6C10PQ
6 Fr 16 cm
20 G
0.9 mm
32 mm Plastic IV Catheter Plastic Shortangle 0.025 in 0.64 mm 80 cm 5 RM*ES6J16HQS
6 Fr 16 cm 20 G

0.9 mm
35 mm Metallic Entry Needle Spring 0.025 in 0.64 mm 80 cm 5 RM*RS6J16PQ
6 Fr 16 cm
20 G
0.9 mm
51 mm Plastic IV Catheter Plastic 0.025 in 0.64 mm 80 cm 5 RM*ES6J16SQ
6 Fr 16 cm 21 G

0.8 mm
35 mm Metallic Entry Needle Spring 0.021 in 0.53 mm 80 cm 5 RM*RS6F16PQ
7 Fr 10 cm 20 G

0.9 mm
35 mm Metallic Entry Needle Spring 0.025 in 0.64 mm 45 cm 5 RM*RS7J10PQ
7 Fr 10 cm
20 G
0.9 mm
51 mm Plastic IV Catheter Plastic 0.025 in 0.64 mm 45 cm 5 RM*ES7J10SQ
7 Fr 10 cm
21 G
0.8 mm
35 mm Metallic Entry Needle Spring 0.021 in 0.53 mm 45 cm 5 RM*RS7F10PQ
7 Fr 10 cm 22 G

0.7 mm
32 mm Plastic IV Catheter Plastic 0.021 in 0.53 mm 45 cm 5 RM*ES7F10SQR
7 Fr 16 cm 20 G

0.9 mm
32 mm Plastic IV Catheter Plastic Shortangle 0.025 in 0.64 mm 80 cm 5 RM*ES7J16HQS
7 Fr 16 cm 20 G

0.9 mm
35 mm Metallic Entry Needle Spring 0.025 in 0.64 mm 80 cm 5 RM*RS7J16PQ
7 Fr 16 cm 21 G

0.8 mm
35 mm Metallic Entry Needle Spring 0.021 in 0.53 mm 80 cm 5 RM*RS7F16PQ
7 Fr 16 cm 22 G

0.7 mm
32 mm Plastic IV Catheter Plastic 0.021 in 0.53 mm 80 cm 5 RM*ES7F16SQR

Please quote above item reference codes when placing an order

References

  1. Rao S. et al. Euro Heart J. 2012; 33(20): 2521-2526.
  2. Saito S. et al. Cath Cardio Inter. 2002; 56(3): 328-332.
  3. Saito S. et al. Catheter Cadiovasc Interv. 1999; 46(2):173-178.
  4. Kiemeneij F. et al. Catheter Cardiovasc Interv 2003;59:161–164
  5. Terumo’s Data on file – ISCD – 123-32-60